ICS-100

RS-232 / RS-422 / RS-485 over Fast Ethernet Media Converter

Cost effective solution for RS-232 / RS-422 / RS-485 to Ethernet application
PLANET ICS-10x series Media Converter / Device Server provide to converts Serial RS-232 / RS-422 / RS-485 communication interface over Fast Ethernet networking. There are RJ-45 and SC connectors and single-mode / multi-mode media for your needs. Ethernet signal that allows two types of segments to connect easily, efficiently and inexpensively. This converter can be used as a stand-alone unit or as a slide-in module to the PLANET Media Converter Chassis (MC-700 / MC-1500/ MC-1500R / MC-1500R48). It's time saving expense for user and SI, no need to replace the existing Serial equipment and software system.

Extend distance
It extends the distance of deploying Serial equipments and hosts. The selectable fiber-Optic wires on the basis of distance are provided. Therefore, this product will perfectly satisfy the diverse demands while providing reliable and efficient network solutions based on the distance and budgets of installation.

Remote Manageable
The ICS-10x make connected Serial equipment becomes IP-based. That also makes them be able to connect to a TCP / IP networking immediately. Each Web-Smart converter is able to manage Web Interface. The powerful Web-Smart Media Converter supports Application mode, Serial operation mode connect alarm and IP address, etc. It helps reduce the amount of valuable time that a network administrator spends detecting and locating network problems, otherwise it requires visual inspection of cabling and equipment. Multiple connection options for large networking environment are available as well.
Ordering Information
ICS-100 RS-232/422/485 over Fast Ethernet Media Converter (RJ-45) – 100m
ICS-101* RS-232/422/485 over Fast Ethernet Media Converter (ST, MM) – 2km
ICS-102* RS-232/422/485 over Fast Ethernet Media Converter (SC, MM) – 2km
ICS-102S15* RS-232/422/485 over Fast Ethernet Media Converter (SC, SM) – 15km
ICS-105A RS-232/422/485 over Fast Ethernet Media Converter (SFP) – Vary on module
(*): Upon by request
Accessories
RKE-DIN DIN-Rail Mounting Kit
Access Control System – traditional installation
Most of the enterprise and government use access control plate and Mifare or RFID to authorize entrance identity. With traditional deploy, access control machine use RS-232 or RS-485 serial interface and cables connect to login server. With connection to ICS-10x Serial over Fast Ethernet Converter, the access control machine is able to be extend over longer distances via Ethernet. Or the ICS-10x can be linked to a XDSL router to get the internet access capability; the access control can be set and monitored over the internet.

Process Control
To monitor, configure and manage the Robot conveyer including other machines in manufacturing, PLC (Programmable Logical Control) is required. The PLC is used to drive above the manufacturing process. The ICS-10x can be set to TCP Server mode and connect the PLC. The administrator can configure and set command settings through Fast Ethernet intranet to control the PLC, the administrator and workstation. There is no need to be always by the side of the I/O machine.

RTU Data Collect – UDP Mode
Connect with RTU (Remote Terminal Unit) to collect and monitor the data of waves, signal and power utilization. ICS-10x can be used set-up UDP mode and send data over Fast Ethernet to Local server or over internet to remote server automatically.

Surveillance motion control – Pair Connection Mode
Using pair connection along with fiber optical patch cord, the ICS-10x extend RS-232 / RS-422 / RS-485 interfaces distance from surveillance and scanner to the control keyboard/joystick which is installed in the remote monitor center.
Ordering Information
ICS-100 RS-232/422/485 over Fast Ethernet Media Converter (RJ-45) – 100m
ICS-101* RS-232/422/485 over Fast Ethernet Media Converter (ST, MM) – 2km
ICS-102* RS-232/422/485 over Fast Ethernet Media Converter (SC, MM) – 2km
ICS-102S15* RS-232/422/485 over Fast Ethernet Media Converter (SC, SM) – 15km
ICS-105A RS-232/422/485 over Fast Ethernet Media Converter (SFP) – Vary on module
(*): Upon by request
Accessories
RKE-DIN DIN-Rail Mounting Kit
Serial Interface
• One RS-232 / 422 / 485 port to one 10/100Base-TX or 100Base-FX Media Converter
• Cost effective solution for RS-232 to Ethernet application
• Supports RS-232, 4-wire RS-422 or 2/4-wire RS485 operation
• Asynchronous serial data rates up to 921600b/s

Ethernet Interface
• Complies with IEEE 802.3, IEEE 802.3u 10/100Base-TX standard
• Supports auto MDI/MDI-X function on RJ-45 Port

Smart Functions
• Standard TCP / IP interface and versatile operation modes
• Software Protocol Support ARP, ICMP,TCP / IP, UDP, HTTP server, DHCP client,
 Telnet server/client
• Built-in IP-Base Web interface for remote management
• Serial Operation mode selected via Web management
• Pair Connection mode for connecting two serial devices over a network
• PLANET Smart Discovery utility automatically finds PLANET devices on the network
• Firmware upgrade via HTTP protocol

Hardware
• Compact size for easy Installation:
• Standalone - Wall mountable or DIN-Rail mounting (Optional accessory)
 -Co-work with PLANET MC family Media Chassis (MC-700 / MC-1500/ MC-1500R / MC-1500R48)
 -LED indicators for easy network diagnose
• Reset Button at the front panel for reset to factory default
Ordering Information
ICS-100 RS-232/422/485 over Fast Ethernet Media Converter (RJ-45) – 100m
ICS-101* RS-232/422/485 over Fast Ethernet Media Converter (ST, MM) – 2km
ICS-102* RS-232/422/485 over Fast Ethernet Media Converter (SC, MM) – 2km
ICS-102S15* RS-232/422/485 over Fast Ethernet Media Converter (SC, SM) – 15km
ICS-105A RS-232/422/485 over Fast Ethernet Media Converter (SFP) – Vary on module
(*): Upon by request
Accessories
RKE-DIN DIN-Rail Mounting Kit
Serial Port
Interface RS-232 / RS-422 / RS-485
Connector 3-in-1 DB9
Baud rate (Data Rate) 110bps to 921Kbps
Data Bits 5,6,7,8
Stop Bit 1,2
Flow Control None, RTS / CTS, Xon / Xoff
Signals RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-
RS-485(2-wire): Data+, Data-
RS-485(4-wire): Tx+, Tx-, Rx+, Rx-
Fast Ethernet Port
Standard 10/100Base-TX
Connector RJ-45
Mode -
Distance 100m
Optical Wavelength -
Cable Twisted-pair
Protection Built-in 1.5KV magnetic isolation
Hardware
LED Indicators System: Power
TP or Fiber Port: Link / Active
Serial Port: Serial port mode, RS-232, RS-422 or RS-485
Management Web Management
PLANET Smart Discovery Utility
VCOM
Operation Mode Virtual COM Port
TCP Server
TCP Client
UDP Client
Pair Connection
Dimension (W x D x H) 97 x 70 x 26 mm
Weight 200g
Power Supply External Power Adaptor 5V DC / 2A max.
Power Consumption 5.5 Watts (max)
Mechanical Metal
Environment Operating Temperature: 0~50 Degree C
Storage Temperature: -10~70 Degree C
Operating Humidity: 10%~90% RH
Storage Humidity: 5%~90% RH
Emissions FCC Class A, CE Certification Class A
Standards • IEEE 802.3 10Base-T,
• IEEE 802.3u 100Base-TX / 100Base-FX
• EIA / TIA RS-232 / 422 / 485
Regulatory Approval RoHS
Compatible Media Converter Chassis MC-700 / MC-1500/ MC-1500R / MC-1500R48
Note Reset Button at the rear panel for reset to factory default
Ordering Information
ICS-100 RS-232/422/485 over Fast Ethernet Media Converter (RJ-45) – 100m
ICS-101* RS-232/422/485 over Fast Ethernet Media Converter (ST, MM) – 2km
ICS-102* RS-232/422/485 over Fast Ethernet Media Converter (SC, MM) – 2km
ICS-102S15* RS-232/422/485 over Fast Ethernet Media Converter (SC, SM) – 15km
ICS-105A RS-232/422/485 over Fast Ethernet Media Converter (SFP) – Vary on module
(*): Upon by request
Accessories
RKE-DIN DIN-Rail Mounting Kit

Datasheet

Date Version Description Download
2008-04-22 1.0 ICS-100

Firmware

Date Version Description Download
2012-12-28 1.8b121009 Bug Fixed - DHCP Enable, the system will recheck after every 10 seconds.
2011-10-15 1.7b110927 1) Fix the catch CSS issue when clear cookie.
2) Fix the Client reply signal loss
3) Change Inactive Timeout to be "Second"
2010-11-05 1.6b101022 Bug Fixed
1.Fix the change IP address issue.
2.Fix the UDP client mode issue.
3.Fix the software reset default that IP address can not become to default IP address.
2009-02-25 1.3b090114 Version 1.3b Firmware
2008-12-05 1.2b081009A Version 1.2b Firmware
2008-12-01 1.1a080611 Version 1.1a Firmware

Quick Guide

Date Version Description Download
2009-07-15 1.1 Quick Install Guide
2008-05-19 1.0 Quick Install Guide for ICS-100/102/102S15

User's Manual

Date Version Description Download
2009-07-15 1.3 User's Manual
2009-04-20 1.2 User's Manual
2008-04-15 1.1 User's Manual

Utility

Date Version Description Download
2009-03-02 3.1 Utility release

EC Declaration

Date Version Description Download
2008-06-24 1.0 Initial Release
Ordering Information
ICS-100 RS-232/422/485 over Fast Ethernet Media Converter (RJ-45) – 100m
ICS-101* RS-232/422/485 over Fast Ethernet Media Converter (ST, MM) – 2km
ICS-102* RS-232/422/485 over Fast Ethernet Media Converter (SC, MM) – 2km
ICS-102S15* RS-232/422/485 over Fast Ethernet Media Converter (SC, SM) – 15km
ICS-105A RS-232/422/485 over Fast Ethernet Media Converter (SFP) – Vary on module
(*): Upon by request
Accessories
RKE-DIN DIN-Rail Mounting Kit